15 research outputs found

    Sustained low efficiency dialysis should not be interrupted for performing transpulmonary thermodilution measurements

    No full text
    Abstract Background Treatment of multiple organ failure frequently requires enhanced hemodynamic monitoring. When renal replacement is indicated, it remains unclear whether transpulmonary thermodilution (TPTD) measurements are influenced by renal replacement therapy (RRT) and whether RRT should be paused for TPTD measurements. Our aim was therefore to investigate the effect of pausing RRT on TPTD results in two dialysis catheter locations. Materials and methods In total, 62 TPTD measurements in 24 patients (APACHE: 32 ± 7 [mean ± standard deviation (SD)]) were performed using the PiCCO™ system (Pulsion, Germany). Patients were treated with sustained low efficiency dialysis (SLED; Genius™ system, Fresenius, Germany) as RRT. Measurements were taken during ongoing hemodialysis (HD, HDO), during paused HD (HDP) and immediately after termination of HD and blood restitution (HDT). Dialysis catheters were placed either in the superior vena cava (SVC, 19 times) or in the inferior vena cava (IVC, 5 times). Statistical analysis was performed to assess the effects of the measurement setting, SLED (blood flow rate) and the catheter location, on cardiac index (CI), global end-diastolic volume index (GEDVI) and extravascular lung water index (EVLWI) as measured by TPTD. Multilevel models were used for the analysis due to the triplicate measurements and due to 12 out of 19 SVC and 2 out of 5 IVC patients having more than one TPTD measured. Results CI and GEDVI were significantly higher at time point HDP compared to both HDO and HDT. In contrast, values for EVLWI were lower at HDP when compared to HDO and HDT. These findings were independent of the site of dialysis catheter insertion and blood flow rate. Conclusions PiCCO™ measurements assessed at paused SLED significantly deviate from ongoing and terminated SLED. Therefore, the dialysis system should not be paused for measurements. TPTD measurements in patients with PiCCO monitoring seem sufficiently reliable during ongoing SLED as well as after its termination. An effect of dialysis catheter location (SVC vs IVC) and blood flow rate on PiCCO™ measurements could not be shown

    Ibuprofen plasma concentration profile in deliberate ibuprofen overdose with circulatory depression treated with therapeutic plasma exchange: a case report

    No full text
    Background Inquiries relating to ibuprofen overdose have more than tripled in the last ten years in our poison control center. Although the vast majority of cases have a benign clinical course, there are few severe or even fatal cases present with refractory circulatory failure. Case presentation We describe a case of a 48 year-old male with suicidal mono-ingestion of approximately 72 g ibuprofen. Despite an initial rapid spontaneous drop in the total ibuprofen plasma concentration (IPC) from 550 to 275 mcg/mL within the first 5 h after admission, the patient developed a circulatory failure, refractory to aggressive fluid resuscitation and high doses of vasopressors. Due to ibuprofen’s favorable pharmacokinetics (>95% bound to albumin, low volume of distribution) and in the absence of specific therapeutic alternatives thereby avoiding escalating vasopressor doses, therapeutic plasma exchange (TPE) for extracorporeal elimination of ibuprofen was considered as a therapeutic rescue option. An improvement of hemodynamics with a significant reduction of vasopressors was observed with TPE-initiation. However, neither the observed IPC-profile nor a pharmacokinetic (PK) simulation provided evidence for a quantitative effective elimination of ibuprofen by TPE. Based on PK-modeling we calculated an overall ibuprofen half-life of 17.2 h for the entire observation period over 5 days. Conclusions To our knowledge this is the first report of a severe ibuprofen-mono intoxication treated with TPE and providing serial IPCs over a period of five days, indicating an estimated fivefold overall-elimination half-life of 17.2 h. Despite TPE clinically improved persistent hemodynamic instability, this procedure was neither consistent with the observed IPC-profile nor correlated with a meaningful quantitative elimination of ibuprofen

    Lethal outcome of granulomatous acanthamoebic encephalitis in a man who was human immunodeficiency virus-positive: a case report

    No full text
    Abstract Background Acanthamoeba species can cause disseminating infections in immunocompromised individuals. Case presentation Here, we report a case of granulomatous acanthamoebic encephalitis with a lethal outcome in a 54-year-old German man who was human immunodeficiency virus-positive. The diagnosis was based on symptoms of progressive neurological deficits, including sensorimotor paralysis of his right leg and deteriorating alertness. Due to the rapid course and rather late diagnosis of the infection, effective treatment could not be applied and he died 12 days after hospital admission. Conclusions To the best of our knowledge, this is the second case of granulomatous acanthamoebic encephalitis reported within Germany. Our case highlights the importance of early diagnosis of granulomatous acanthamoebic encephalitis to prevent fatal outcome

    Additional file 1: of Ibuprofen plasma concentration profile in deliberate ibuprofen overdose with circulatory depression treated with therapeutic plasma exchange: a case report

    No full text
    Measured Ibuprofen in plasma (IPC), creatinine and norepinephrine doses, and predicted IPC elimination. Raw Data Set of the measured Ibuprofen in plasma, creatinine and norepinephrine levels and the calculated values for the interpolation of predicted IPC elimination. A - Time course of Ibuprofen plasma concentration measured/predicted and serum-creatinine. B – Norepinephrine-dose and blood pH over time. C – Logarithmic plasma concentration of Ibuprofen (measured/predicted) over time. (XLSX 53 kb

    Figure_1ABC_data_04_2017.xlsx

    No full text
    Additional File to "Ibuprofen plasma concentration profile in deliberate ibuprofen overdose with circulatory depression treated with therapeutic plasma exchange: a case report"<br

    Lethal outcome of granulomatous acanthamoebic encephalitis in an HIV-positive patient – a case report

    No full text
    Figures showing Acanthamoeba spp. trophozoites in different stainings, Picture of brain lesions; Tables summarizing diagnostic procedures and initial treatment<br

    Independent validation of the ICU requirement score in a cohort of acutely poisoned adults

    No full text
    <p><b>Objective:</b> To independently validate the predictive value of the intensive care requirement score (IRS) in unselected poisoned patients.</p> <p><b>Design:</b> Retrospective chart review.</p> <p><b>Patients and methods:</b> Five hundred and seventeen out of 585 admissions for acute intoxications could be analyzed. Eleven were excluded for a condition already requiring intensive care unit (ICU) support at admission (e.g., preclinical intubation). A further 57 admissions were excluded due to missing data. The IRS was calculated using a point-scoring system including age, Glasgow Coma Scale, heart rate, type of intoxication, and preexisting conditions. It was then compared to a composite endpoint indicating an ICU requirement (death in hospital, vasopressors, need for ventilation). The endpoint and the point-scoring system were identical to the original publication of the score.</p> <p><b>Results and conclusion:</b> Twenty-three out of 517 patients had a complicated clinical course as defined by meeting the endpoint definition. Twenty-one out of 23 complicated courses had a positive IRS (defined as greater or equal 6 points), as compared to 255/494 patients with an uncomplicated clinical course (<i>p</i> < .001, Fisher’s exact test). One patient (with a positive IRS) died. The negative predictive value of the IRS was 0.99 (95% CI: 0.97–1), the sensitivity was 0.91 and the specificity 0.48. In conclusion, the IRS is significantly linked to outcome. While a negative IRS virtually excludes the need for ICU care, a positive IRS has a positive predictive value too low to be used for risk stratification. The IRS could also be applied to unselected admissions of poisoned patients.</p
    corecore